ROCKWOOL® SP Firestop OSCB 44

Product Code: RC5120RW

Specifically designed for use only in conjunction with ROCKWOOL RAINSCREEN DUO SLAB®, SP Firestop OSCB 44* forms an open-state cavity fire barrier within the building façade, allowing for an open cavity of up to 44mm for ventilation and drainage. This product provides up to 120 minutes integrity and insulation.

Description

Designed for use only in conjunction with ROCKWOOL RAINSCREEN DUO SLAB, SP Firestop OSCB forms an open-state cavity fire barrier within a rainscreen cavity. The product comprises of a continuous intumescent strip fixed to the leading edge of a foil faced stone wool barrier, encapsulated by a weather-resistant polythene sleeve. Fully tested to ASFP TGD 19, the combination of non-combustible insulation with an effective intumescent supports the construction of safe façade systems and aids the design of high-rise buildings over 18m in height. Installed horizontally and designed to ensure an appropriate open air space is maintained, SP Firestop OSCB is suitable for cavity widths up to 425mm (OSCB 44).

  • Fully tested to “ASFP Technical Guidance Document 19: Fire resistance Test for ‘open-state’ cavity barriers used in the external envelope or fabric of buildings”
  • Up to 120 minutes fire integrity and insulation
  • Provides 25mm or 44mm airspace
  • Satisfies NHBC and CWCT guidance for ventilation gaps at fire barrier locations
  • Weather resistant
  • Easy site storage and handling

Product Data Sheet

Download